Dry Block Heater Specification

  • Measuring Range
  • Ambient to 120C
  • Resolution
  • 0.1C
  • Operating Voltage
  • 230V AC
  • Display Type
  • Digital LED display
  • Frequency
  • 50/60 Hz
  • Max Height
  • Approx. 135 mm
  • Interface Type
  • Keypad controls
  • Specimen Size
  • Various tube sizes (0.5/1.5/2.0 mL possible)
  • Equipment Type
  • Dry Block Heater
  • Application
  • Sample incubation, Enzyme reactions, General laboratory heating
  • Power Supply
  • 230V AC, 50/60 Hz
  • Humidity
  • Up to 80% RH
  • Temperature
  • Ambient to 120C
  • Accuracy
  • 0.5C
  • Automation Grade
  • Semi-automatic
  • Features
  • Interchangeable blocks, Over-temperature protection, Compact design
  • Number of Specimens
  • 1-4 blocks (varies by model)
  • Response Time
  • Rapid heating (<15 minutes to max temp)
  • Test Range
  • Ambient to 120C
  • Mounting Type
  • Benchtop
  • Usage
  • Laboratory, Research, Clinical
  • Capacity
  • 24 x 1.5 mL tubes (or as per block design)
  • Machine Weight
  • Approx. 3 kg
  • Control Mode
  • Digital control
  • Storage Temperature
  • -10°C to 50°C
  • Block Material
  • High-grade anodized aluminium
  • Timer Function
  • 0-999 minutes
  • Over Temperature Protection
  • Yes, with alarm signal
  • Ambient Operating Range
  • 5°C to 40°C
  • Dimension (L x W x H)
  • 270 x 190 x 135 mm
  • Heating Element
  • High-efficiency, resistance heater
  • Block Interchangeability
  • Yes, compatible with multiple block types
 
 

About Dry Block Heater

Digital controls and display of time and temperature Set up Block Material :Aluminium alloy

  • Block Type : Full
  • Diameter of probe tube:5 millimeter
  • Coating of probe tube: SafeCoat
  • Tube Types:Standard Test Tubes
  • Temperature Range,(+/-) :Ambient 5 deg C to 130 deg C
  • Temperature Accuracy,(+/-) : (Deg C)0.5
  • Relative Humidity Tolerance,(
  • Temperature Uniformity at 37 Deg C,) (+/-) (Deg C): 0.5
  • Voltage : 100-250V; 50-60Hz


High-Performance Heating Efficiency

Equipped with high-efficiency resistance heaters and rapid response time, the Dry Block Heater quickly reaches set temperatures in less than 15 minutes. Its precision engineering ensures stable and uniform heating, while the digital LED display provides clear temperature readouts for reliable monitoring and control during critical sample heating applications.


Customizable Block Interchangeability

Designed for versatility, this heater accepts multiple block types compatible with a range of tube sizes (0.5/1.5/2.0 mL), supporting up to 24 samples per run, depending on block configuration. The modular block system allows seamless adaptation, catering to diverse laboratory needs from clinical diagnostics to research settings.


Reliable Over-Temperature Protection

Safety is integral with an advanced over-temperature protection system that automatically activates if set limits are exceeded, accompanied by an alarm signal for immediate alert. This ensures sample integrity and protects users and equipment from overheating risks during intensive laboratory processes.

FAQ's of Dry Block Heater:


Q: How do you operate the Dry Block Heater for sample incubation or enzyme reactions?

A: To use the Dry Block Heater, select the appropriate block for your tube size, load your specimens, set the desired temperature and timer via the digital keypad, and monitor progress on the LED display. Its rapid heating function ensures your samples reach target temperature quickly and remain stable throughout the process.

Q: What safety features does the Dry Block Heater include for laboratory use?

A: The device is equipped with an over-temperature protection system that automatically engages if temperatures exceed preset limits, coupled with an audible alarm signal. This safeguards samples and operators from potential overheating, maintaining a safe laboratory environment.

Q: When is block interchangeability beneficial in laboratory applications?

A: Interchangeable blocks allow users to switch easily between different tube sizes and quantities, making the Dry Block Heater adaptable for various protocols-such as handling 0.5, 1.5, or 2.0 mL tubes-without the need for multiple devices. This flexibility is especially useful when incubating multiple specimen types.

Q: Where can the Dry Block Heater be installed and used?

A: Designed as a compact benchtop unit, the heater is suitable for laboratories, research centers, and clinical settings. Operating within ambient ranges of 5C to 40C and humidity up to 80% RH, it functions effectively in standard laboratory environments.

Q: What is the accuracy and measurement range of this equipment?

A: The Dry Block Heater maintains a high accuracy of 0.5C and offers a temperature measuring range from ambient up to 120C, with 0.1C resolution. This precision supports tasks requiring strict thermal control, such as sample incubation and enzyme reactions.

Q: How many specimens can be processed at once and what are the sample size options?

A: Depending on the block used, the heater can accommodate 1 to 4 blocks and up to 24 tubes of 1.5 mL each (or other tube sizes, based on block design). This allows for concurrent processing of multiple samples, increasing laboratory efficiency.

Q: What are the main benefits of using the Dry Block Heater in a laboratory setting?

A: Key benefits include accurate and rapid heating, customizable block configurations for different sample formats, reliable over-temperature protection, and a user-friendly digital interface. Its semi-automatic operation and compact design optimize workflow and space utilization in laboratories.

Price 20000 INR/ Number

  • Minimum Order Quantity
  • 2 Number
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing & Measuring Equipments Category

Digital Melting Point Appartus

Digital Melting Point Appartus

Usage : Laboratory, pharmaceutical, and research applications

Features : Digital temperature display, programmable ramp rate, buzzer alarm, builtin cooling fan

Conductivity Meter

Conductivity Meter

Usage : Testing & Measurement

Product Type : Conductivity Meter

Voltage : 110220 Volt (v)

Color : White

Material : Plastic

Infrared Moisture Balance

Infrared Moisture Balance

Usage : Laboratory

Product Type : Infrared Moisture Balance

Features : Easy installation, Low maintenance, Quality tested

Voltage : 220 Volt (v)

Color : White

Material : Metal

Digital Ph Meter

Digital Ph Meter

Usage : Laboratory

Product Type : Digital Ph Meter

Features : Accuracy, Durable, Light Weight, Low Power Comsumption, Stable Performance

Voltage : 220 Volt (v)

Color : White

Material : Cast Iron, Plastic



Products Description